Supplier to Saudi Aramco

BM(D)X-Series Explosion Protected Distribution Box

  • Home
  • Product
  • BM(D)X-Series Explosion Protected Distribution Box

BM(D)X-Series Explosion Protected Distribution Box

  • Explosion protection

-IECEx(IEC)

-ATEX(CENELEC,EN)

-China Ex(GB)

  • Application in hazardous area

-Zone 1 and Zone2,

-Zone 21 and Zone 22

  • This product is combined with flame-proof cavity andan increased safetycavity,the branch switch and the main switch are operated by the operating handle on the panel.
  • Modular structure,The enclosures can be combined and installed tomeet the various requirements of power distribution systems.
  • The product is wired with terminals and components.
  • The circuit breaker usingmetal handle with frozen-resistant and can beequipped with a padlock.
  • Withstop plug for cable entry holes,cable entry devices are optional.
  • Pleasespecifythe special requirements when ordering.

Nomenclature

Note:

1.Please specify the number, specification and position of the cable entry holes;

2.Please provide the electrical schematic diagram, please specify the needed of photoswitch, time switch, AC contactor,thermal relay or others;

3.Please specify the special requirements;

4.The rain shade is customizable by requirements.

Selection table of BMX口series

TypeMain switchNumber of
branch
Branch switchCurrent of branchNumber of
indicator
Cable entriesWeight (Kg)
BMX□-2/□/K□MCB or MCCB

Current:Max.100A
2MCB
1P/2P
1A,2A,4A,
6A,10A,16A,
20A,25A,32A,
50A,63A
1+21XM40X1.5+2XM25X1.527.5
BMX□-4/□/K□41+41XM40X1.5+4XM25X1.534
BMX□-6/□/K□61+61XM40X1.5+6XM25X1.541
BMX□-8/□/K□81+81XM40X1.5+8XM25X1.548
BMX□-10/□/K□101+101XM40X1.5+10XM25X1.554.5
BMX□-12/□/K□121+121XM40X1.5+12XM25X1.561.5
BMX□-2/□ 2MCB
1P/2P
1A,2A,4A,
6A,10A,16A,
20A,25A,32A,
50A,63A
21XM40X1.5+2XM25X1.58.5
BMX□-4/□441XM40X1.5+4XM25X1.515
BMX□-6/□661XM40X1.5+6XM25X1.522
BMX□-8/□881XM40X1.5+8XM25X1.529
BMX□-10/□10101XM40X1.5+10XM25X1.535.5
BMX□-12/□12121XM40X1.5+12XM25X1.542.5
Description
TypeMain switchNumber of
branch
Branch
switch
Current of
   branch
Number of
indicator
Cable entriesWeight (Kg)
BDX□-2/□/K□MCB or MCCB
Current Max.250A
2MCB
3P

1A,2A,4A,
6A,10A,16A,
20A,25A,32A,
40A,50A,63A
1+21XM50X1.5+2XM25X1.527.5
BDX□-4/□/K□41+41XM50X1.5+4XM25X1.534
BDX□-6/□/K□61+61XM50X1.5+6XM25X1.541
BDX□-8/□/K□81+81XM50X1.5+8XM25X1.548
BDX□-10/□/K□101+101XM50X1.5+10XM25X1.554.5
BDX□-12□/□/K□121+121XM50X1.5+12XM25X1.561.5
BDXD □-2/D ——2
MCB
3P
1A,2A,4A,6A,
10A,16A,20A,
25A,32A,40A,
50A,63A
21XM50X1.5+2XM25X1.58.5
BDX□-4/□441XM50X1.5+4XM25X1.515
BDX□J-6/□661XM50X1.5+6XM25X1.522
BDX□-8/□881XM50X1.5+8XM25X1.529
BDX□-10/□10101XM50X1.5+10XM25X1.535.5
BDX□-12/□12121XM50X1.5+12XM25X1.542.5

Electrical Schematic Diagram

Ex marking Gas Ex II2 G Ex de IIB T6/T5/T4 Gb Ex de IIB T6/T5/T4 Gb Ex d e IIB T6/T5/T4 Gb
Ex II2 G Ex de IIC T6/T5/T4 Gb Ex de IIC T6/T5/T4 Gb Ex d e IIC T6/T5/T4 Gb
Dust Ex II2D Ex tb IIIC T80℃/T95℃ Db IP66 Ex tb IIC T80℃/T95℃ Db IP66 Ex tD A21 IP66 T80℃/T95℃
Conformity to standards IEC 60079-0,IEC 60079-1,IEC 60079-7,IEC 60079-31
EN 60079-0,EN 60079-1,EN 60079-7,EN 60079-31
GB3836.1,GB3836.2,GB3836.3,GB12476.1,GB12476.5
Enclosure
material
Enclosure Aluminum alloy enclosure,powder coated,Industrial grey with dark lines texture(RAL7035)
Rain shade Bended steel plate surface powder coated,industrial grey with dark lines texture (RAL7035)or
stainless steel 304/316,please note when needed
Exposed fasteners Stainless steel
Components Flame-proof
enclosure
Miniature circuit breaker (MCB),leakage protection device provided by requirements
Molded case circuit breaker(MCCB),leakage protection device provided by requirements
Increased
safety cavity
enclosure
World famous brand of terminal block
HI0101 explosion-proof control button,refer to P B/122 for technical parameters
HL0102 explosion-proof indicator,refer to P B/130 for technical parameters
HL0101-S explosion-proof control switch,refer to P B/126 for technical parameters
HL0109 explosion-proof ammeter,refer to P B/120 for technical parameters
Rated voltage 24,36,110,220,230,380,415V AC;
24,36,110,220V DC
Rated current Main circuit 6A≤le≤250A
Branch circuit 1A≤le≤63A
Frequency 50Hz/60Hz
Temperature
class
Main circuit Branch circuit Main circuit Branch circuit Main circuit Branch circuit
Current 80A≤le≤250A le≤63A   les100A les63A le≤63A le≤50A
Gas T4 T5 T6
Dust T95℃ T80℃ T80℃
Degree of protection IP66
Ambient temperature IIB type:-40℃~+55℃,IIC type:-20℃~+55℃
Cable entry Default G1/2~G3,HLBM-□ for recommended,see page D/07~D/20 for details
Optional M20X1.5~M90×1.5,NPT1/2~G3,HLBM-□ for recommended,see page D/07~D/20 for details
Inlet direction Bottom in and bottom out,upon request
Installation method Wall type (default)
Stand type (optional)

 

 

Related products

Request a Quote

Get professional explosion-proof product solutions to keep you safe!